The B4 and B6 anchors
are generally associated with a medium percussive installation. These
ground anchors require more powerful hand held hydraulic percussive breakers
to install them. Loadlocking is completed using a hydraulic loadlocking
unit.
Where ground conditions are hard or large quantities of ground anchors are to be installed this type of equipment can also be used to install the S6 and S8 anchors. In situations where the ground is soft this equipment may be useful for installing B8 anchors. |
![]() |
| STAGE ONE - DRIVING THE GROUND ANCHOR | |||||
![]() ![]() |
Drive the ground anchor system
into the ground to the required installation depth. |
||||
| STAGE TWO - REMOVING THE RODS | |||||
![]() ![]() |
Remove the drive rod from
the body of the ground anchor, either by hand or using rod removing equipment. |
||||
| STAGE THREE - LOADLOCKING | |||||
![]() ![]() |
Loadlock the ground anchor system into its working position by applying a load to the wire tendon. | ||||
| Platipus
Anchors Limited - UK Office Kingsfield Business Centre, Philanthropic
Road, REDHILL, Surrey, RH1 4DP, England. Tel: +44 (0) 1737 762300 Fax: +44 (0) 1737 773395 Email: info@platipus-anchors.com |
|||
| Platipus
Anchors Inc- USA Office 2008 Garner Station Boulevard, Raleigh, NC 27603,
USA. Tel: 866 PLATIPUS (752 8478) Fax: 919 859 9597 Email: info@platipus-anchors.com |
|||